Comparison of Mechanical and Electrical Downtilt

Comparison of Mechanical and Electrical Downtilt
 



 Mechanical
  • The downtilt angle varies over the horizontal
    beamwidth. Patterns measured ±90° from the center of
    the beam have decreasing tilt angle until there is no
    tilt 90° from the main beam.
  • The horizontal half-power beam width increases with
    greater downtilt angle.
  • The resulting gain reduction depends on azimuth
    direction.



Electrical
  • There is uniform downtilt over the whole
    azimuth range.
  • The horizontal half-power beamwidth is
    independent of the downtilt angle.
  • There is identical gain reduction in all azimuth
    directions.
sumber : Katherin Technical Bulletin #116 January 1999